text.skipToContent text.skipToNavigation

Printed circuit Board (PCB) Assembly Cam-14 v2

2028778-003
2028778-001 900995-004
Nuovo
ECG Diagnostico
GE HealthCare
GE HealthCare
N/A
Aggiungi a lista dei desideri
Accedi e aggiungi al carrello
Accedi e aggiungi al carrello
Selezionare data
Approvazione seconda opinione necessaria

Immettere il numero approvazione e inviare per aggiungere articolo(i) al carrello.

Numero approvazione

Please enter approval number

OR

Non conosci il tuo numero approvazione? Chiamare il numero 800-437-1171
Immettere opz 1 per le prime tre richieste e rendere disponibile l’ID sistema.

Aggiungendo uno o più articoli al carrello e inviando l’ordine senza il
numero di approvazione, si verrà richiamati da GE prima della conferma dell’ordine
per la spedizione.

Approvazione seconda opinione necessaria

Select your approver's name and submit to add item(s) to your cart

Approver Name

Please Select Approver Name

OR

Don't know your approval number? Call 800-437-1171
Enter opt 1 for the first three prompts, and have your System ID available.

If you add item(s) to cart and submit your order without
selecting an approver, GE will contact you before your order
can be confirmed for shipment.


Informazioni sul prodotto

The Printed Circuit Board (PCB) Assembly Cam-14 HD is used in Diagnostic Electrocardiogram (ECG) machines. The CAM-14 acquisition module is intended to acquire the analog ECG signal, digitize it and transmit the signal to a host unit. The PCB (Printed Circuit Board) is assembled in the CAM-14 HD. The circuitry is designed to protect the host unit against the effects of cardiac defibrillator discharge to ensure recovery. CAM-HD module has 3 software pieces that need to be programmed to flash memory during the board assembly. Two of these pieces are programmed to the Atmel AT45DB041 Dataflash (U113), and the third to the on chip flash memory of the AT Tiny2313 (U121) chip. The PCB consists of IC’s, diodes, resistors, connectors, capacitors, ferrite bead, LED and transistors. The PCB is mounted using the provided screws. Cables are connected to the main PCB. Fasteners are used as connections to ground panes on PCB. The ECG signal input is isolated and defibrillation-proof only in conjunction with CAM14. It is being used in CASE, MS CARESCAPE™ Monitor B850, CardioSoft, UL Vivid S6, Stress Other, UL Voluson P8, Premium Carts Other, CT SYTEC 8000 1-Slice, MAC 5500 HD, ARC Aisys CardioSoft, CT CTe 1 – Slice, Supplies and other applications.

Parte equivalente

Di seguito sono riportate maggiori informazioni sulle parti equivalenti. Le parti senza un collegamento ipertestuale sono indicate solo a scopo di riferimento e non sono disponibili per l’acquisto online.

Parte equivalenteDettagli parte
2028778-001 PCB ASSY CAM14 V2
900995-004

900995-004